Home > Products > Low Voltage Switchgear > Drawer type low-voltage switchgear
                    Drawer type low-voltage switchgear

                    Drawer type low-voltage switchgear

                    The Drawer type low-voltage switchgear ensures that each functional unit is distinct from the busbar or cable, creating three separate areas for efficient power distribution. This design also incorporates isolation measures between functional units, contributing to the overall reliability and safety of the switchgear. As a result, drawer-type switchgear is widely used in industrial and mining enterprises, high-rise buildings, and centralized control distribution centers that require high power supply reliability. The switchgear's closed steel plate shell houses withdrawable drawers containing electrical components for incoming and outgoing circuits, allowing for easy maintenance and customization.

                    Model:drawer switchgear

                    Send Inquiry

                    Product Description

                    ◆ The MNS low-voltage withdrawable switchgear is suitable for power plants, substations, petrochemicals, metallurgical steel rolling, light sector and textile business, residential communities, high-rise buildings, and other areas as circulation tools for energy conversion, circulation, and control of power systems with air conditioning 50-60Hz and rated operating voltage air conditioning 660V and below.

                    ◆ The GCK low-voltage withdrawable switchgear contains two components: the power distribution center (PC) closet and the electric motor nerve center (MCC). It acts as an a/c 50HZ distribution system with an optimum working voltage of 660V and a maximum functioning current of 3150A. It is used for power distribution, electric motor control, and illumination distribution devices for energy conversion and distribution control.

                    ◆ GCS devices are suitable for huge nuclear power plants, petrochemical systems, and other systems with high automation degrees; a low-voltage total collection of circulation equipment is required for circulation, streamlined control of electric motors, and reactive power settlement in power generation and supply systems with a three-phase a/c regularity of 50 (60) HZ, ranked voltage of 380V (400V) (660V), and rated present of 4000A, which is needed to interface with computer systems.


                    Working conditions of Drawer type low-voltage switchgear

                    ◆ The ambient air temperature shall not exceed+40 ℃, not be lower than -5 ℃, and its average temperature shall not exceed+35 ℃ within 24 hours;

                    ◆ Atmospheric conditions: The air is clean, and the relative humidity does not exceed 50% at the highest temperature of+40 ℃. Higher relative humidity is allowed at lower temperatures, such as 90% at+20 ℃. However, temperature changes should be taken into account as condensation may occur accidentally;

                    ◆ Altitude:The altitude does not exceed 2000m;

                    ◆ This device is suitable for transportation and storage processes at the following temperatures: within the range of -25 ℃ to+55 ℃, it can reach+70 ℃ in a short period of time (not exceeding 24 hours). Under these extreme temperatures, the device should not suffer any irreparable damage and should be able to operate normally under normal conditions;

                    Note:If the above usage conditions cannot be met, it should be resolved through negotiation between the user and the manufacturer;

                    When this device is used on offshore oil drilling and production platforms and nuclear power plants, a separate technical agreement should be signed.


                    Product features of Drawer type low-voltage switchgear:

                    1. The drawer -type electrical switchgear is constructed from 8MF open steel, with installing holes on the sides of the steel with a component of 20mm and 100mm, with a diameter of 9.2 mm.

                    2. The gadgets' practical spaces are isolated from each other, and their compartments are divided into functional unit rooms, busbar areas, and cable television rooms. The functions of each space are independent of each other. The straight main busbar adopts a straight setup behind the electrical switchgear to improve its capacity to withstand electric forces.

                    3. The design of cord areas makes it extremely convenient for wires to enter and exit both up, down, and horizontally.

                    4. The module of the cabinet layer elevation is 160mm, and the rated existing of the device circuit is 400A or less.

                    5. Each MCC cabinet can suit up to 11 drawers per unit or 22 drawers per fifty percent system.

                    6. The drawer inlet and electrical outlet lines make use of adapters with various varieties of the same requirements chip framework according to the size of the current.

                    7. The drawer unit is outfitted with a mechanical interlocking tool.


                    Technical parameters of Drawer type low-voltage switchgear

                    Complies with IEC529 and DIN40050 standards;

                    IP30 for solid protection greater than 2.5mm:

                    IP40 for solid protection greater than 1.0mm:

                    IP54 provides protection against dust and splashing in any direction:

                    When ordering IP54 protection level, it should be negotiated with the manufacturer.


                    Cabinet structure




                    Hot Tags: electric cupboard key,400 amp ct cabinet,outdoor electric cabinet,electric panel cabinet,outdoor weatherproof enclosure cabinet box,power distribution cabinet,cabinet power distribution,600 amp ct cabinet,electric ct cabinet,backless cabinet for fuse box

                    Related Category

                    Send Inquiry

                    Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
                    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
                    Reject Accept